Bar Ball Float Steam Trap

Size
DN15~DN150
Connection
RF, NPT,SW
Pressure
PN10, PN16, PN25,PN40
Materials
Carbon Steel, Low temperature steel, Stainless steel.

Performance/Advantages

Continues discharging saturation condensed water without accumulation,and so get the maximum thermal efficiency.

When steam pressure changes,the ball floating can adjust the opening of valve seat withou indfluence,and so it is stable.

With automatic and manual releaser,and so its exhaust performance is good without airlock and working is smooth without noise.

Excellent sealling performance,with ball structure for sealing piece,no physical deterioration and long useful life.

Working Principle.

when start,the automatic exhaust plant clear away the non-frozen gas in system fast.The temperature rises up with the increasing of steam and hot condensation water and the exhaust plat closes automatically,the ball float rises up with the water level of condensation water and driver the bar for adjusting the opening of valve seat hole,continues to dicharge condensation water.When the condensation water stops,the ball float falls by grvity drive the bar for moving valve plug for closing the seat hole of drain valve.

Application

by automation,speedliness and continuing features,this valve is used for the steam heating equipment,condensation water recovery system and the place where needs removing condesation water at quick speed ,and so stop steam leakage effectively and obtains optimum heating

Main basis for type selection

condesation water loading(discharge)kg/h(select the multiplying power 2-3 times)

Maximum working pressure MPa

Operation pressure differential MPa

Valve Material and nominal pressure

Connection mode and dimension

Use and Maintenance

Confirm the valve material pressure and check if the maximum is suitable for operation condition.

Before install,clean the pepeline and clear away sundries

The installation poisition shall be closed to heating equipment as much as possible.

Install the minimum point of pipe horizontally and the direction of flow should be the same to the lable of valve.

Install steam trap for each heating equipment in case cause influence each other.

under the safe operation of system,open the valve in front of the steam trap,make it rise up to normal station slowy.

Do time-based maintenance for the normal working of steam reap.

Get In Touch

We respect your privacy, Enquiry will send to our sales team, we will reply you with 12 hours.